4 I/O Signal Allocation
4.3 Transmission Data
4-25
HW1485152
HW1485152
[SST-PN-2-PE Board Status]
The status of the SST-PN-2-PE board (the first 8 points of the allocation
area) is indicated as follows.
The value “xxx” of the allocated input signals in the table indicates the first
number of the SST-PN-2-PE board allocated number. In the table above,
where the allocation numbers are 20020 to 20027, “xxx” would be “002”.
SST-PN-2-PE
(PROFINET)
I/O Output 30090 to 30097 10090 to 10097 (OT0065 to OT0072) Output data (7)
30100 to 30107 10100 to 10107 (OT0073 to OT0080) Output data (8)
30110 to 30117 10110 to 10117 (OT0081 to OT0088) Output data (9)
30120 to 30127 10120 to 10127 (OT0089 to OT0096) Output data (10)
30130 to 30137 10130 to 10137 (OT0097 to OT0104) Output data (11)
30140 to 30147 10140 to 10147 (OT0105 to OT0112) Output data (12)
30150 to 30157 10150 to 10157 (OT0113 to OT0120) Output data (13)
30160 to 30167 10160 to 10167 (OT0121 to OT0128) Output data (14)
30170 to 30177 10170 to 10177 (OT0129 to OT0136) Output data (15)
30180 to 30187 10180 to 10187 (OT0137 to OT0144) Output data (16)
1 Board status and system reservation cannot be allocated as IO signal. Also, this data is not able to transmit by
PROFINET.
(Unable to communicate with the main PLC.)
Signal Contents
2xxx0 to 2xxx3 Reserved for the manufacture. The user cannot use these signals.
2xxx4 Indicates the PROFINET communication through PROFINET IO Device mode.
Normal:0 Error: 1
2xxx5 Indicates if communicating with all the IO Device or not through PROFINET IO
Controller mode.
Communicating with all slaves: 0
Communicating with some slaves: 1
2xxx6 Indicates the PROFINET communication status.
Normal: 0 Error: 1
2xxx7 Indicates the operation status of the SST-PN-2-PE board.
Normal: 0 Error: 1