5 Error Indication
5-1
HW1485152
HW1485152
5 Error Indication
SST-PN-2-PE board is provided with LEDs for circuit board status
indication. These LEDs indicate the following conditions.
SYS NET Comments
Off Off Card not running.
Green Off PROFINET protocol stack is stopped.
Green Red blinking Default PROFINET configuration.
Green Green
blinking
Card configured, but not connected to PROFINET
devices/controller.
Green Green Card configured, connected to PROFINET
devices/controller.
Red Green Card is booting.
Red Red Initialization internal error.
• Turn OFF and ON the YRC1000micro main power
to start the system again.
• Check the connection of the SST-PN-2-PE board
and the YRC1000micro PCI Express slot.
• Replace the SST-PN-2-PE board.
1. SYS LED
2. NET LED
3. IRT LED (reserved)
4. SYNC LED (reserved)