8.2 Warning Displays
8.2.3 INDEXER Warning Displays and Troubleshooting
8-50
E55E
A.9F9
Servo ON Failure
Error
The motor is rotating during servo ON
execution.
The main power supply went OFF during
servo ON execution.
Hard wire base block status (HWBB sta-
tus)
Tur n the s e r vo
ON when the
motor is
stopped.
Tur n ON t he
/HWBB1 and
/HWBB2 sig-
nals. Then turn
OFF the /S-ON
signal to first
turn OFF the
servo and then
turn ON the
servo again.
E58E
A.9F9
Data Out-of-
range Error
The specified setting was incorrect in a
parameter or program table write com-
mand.
Check the set-
ting.
E5DE
A.9F9
Homing Method
Unspecified Error
The homing method is not specified.
Starting homing was requested by turning
ON the /HOME signal without setting the
homing method.
Specify the hom-
ing method with
Pn642 =
n.X.
E5EE
A.9F9
Execution Dis-
abled during Pro-
gram Table
Operation Error
There was a request to execute a process
that is not allowed during program table
operation while program table operation
was in progress or on hold.
There was an attempt to change the pro-
gram table while program table operation
was in progress or on hold.
Request execu-
tion of the pro-
cess again after
canceling pro-
gram table oper-
ation by turning
the
/PGMRES signal
ON.
E5FE
A.9F9
Session Conflict
Error
There was a request that could not be exe-
cuted at the same time as the function that
was being executed.
Example:
There was a request to start program table
operation while the program table was
being initialized.
Execute the
operation again
after the execu-
tion of the current
function is com-
pleted.
E61E
A.9F9
Encoder Mis-
match Error
Homing start was requested (i.e., the /
HOME signal was turned ON) when an
absolute encoder is connected.
Check the
Encoder.
Set Pn002 to
n.1 (Use
the absolute
en
coder
as an
incremental
encoder).
E63E
A.9F9
Continuous Stop
Execution Dis-
abled Error
An attempt was made to execute a continu-
ous stop under conditions where it could
not be executed.
Examples:
The coordinates have been set to linear
moving method.
The immediately-preceding table target
position is not ±INFINITE.
The immediately-preceding table target
position is ±INFINITE, but the registration
distance is set.
A value other than 1 has been set for the
execution count.
Execute a contin-
uous stop under
conditions where
it can be exe-
cuted.
Continued on next page.
Continued from previous page.
Error No.
Alarm
Number
Error Name Meaning Corrective Action

Table of Contents