9.2 List of Parameters
9.2.2 List of Parameters
9-39
Pn635
2
Output Signal Selec-
tions 10
0000h to
6666h
0654h All
After
restart
Setup
Pn636
2
Output Signal Selec-
tions 11
0000h to
0666h
0000h All
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
/POUT0 (Programmable Output 0) Signal Allocation Reference
0 Disabled (the above signal output is not used).
page 6-5
1 Output the signal from the CN1-25 or CN1-26 output terminal.
2 Output the signal from the CN1-27 or CN1-28 output terminal.
3 Output the signal from the CN1-29 or CN1-30 output terminal.
4 Output the signal from the CN1-37 output terminal.
5 Output the signal from the CN1-38 output terminal.
6 Output the signal from the CN1-39 output terminal.
n.X
/POUT1 (Programmable Output 1) Signal Allocation Reference
0 to 6
The settings are the same as for /POUT0 (Programmable Output
0) Signal Allocation.
page 6-5
n.X
/POUT2 (Programmable Output 2) Signal Allocation Reference
0 to 6
The settings are the same as for /POUT0 (Programmable Output
0) Signal Allocation.
page 6-5
n.X
/POUT3 (Programmable Output 3) Signal Allocation Reference
0 to 6
The settings are the same as for /POUT0 (Programmable Output
0) Signal Allocation.
page 6-5
n.X
/POUT4 (Programmable Output 4) Signal Allocation Reference
0 Disabled (the above signal output is not used).
page 6-5
1 Output the signal from the CN1-25 or CN1-26 output terminal.
2 Output the signal from the CN1-27 or CN1-28 output terminal.
3 Output the signal from the CN1-29 or CN1-30 output terminal.
4 Output the signal from the CN1-37 output terminal.
5 Output the signal from the CN1-38 output terminal.
6 Output the signal from the CN1-39 output terminal.
n.X
/POSRDY (Homing Completed Output) Signal Allocation Reference
0 to 6
The settings are the same as for /POUT4 (Programmable Output
4) Signal Allocation.
page 6-5
n.X
/DEN (Positioning Reference Distribution Output) Signal Allocation Reference
0 to 6
The settings are the same as for /POUT4 (Programmable Output
4) Signal Allocation.
page 6-5
n.X Reserved parameter (Do not change.)