Loading...
10 European Standards
YASKAWA ELECTRIC TOBP C730600 89D YASKAWA AC Drive Option SI-EP3 Installation Manual 63
Figure 26
Figure 27 Ground Area
n Option Installation for CE Compliance: Models PG-, DI-, DO-,
AI-, AO-, SI-
Figure 27
Figure 28 Option Installation for CE Compliance (PG-, DI-, DO-, AI-, AO-, SI-)
A Braided shield cable C Cable clamp (conductive)
B–Metal panel
CB
A
L1
L2
L3
L1
L2
L3
R
CN5-B,
CN5-C
CN5-A,
CN5-B,
CN5-C
CN5-A
S
T
PG-
Drive
EMC filter PG option
DI-,
DO-,
AI-,
AO-
I/O option
SI-
Communication
option
Encoder
I/O device
Master
Cable clamp
Enclosure panel
Three-
phase
power
supply
Cable clamp
Cable clamp
A1000