What to do if YASKAWA Controller shows Option Card External Fault?
E
Eric LaneAug 21, 2025
If your YASKAWA Controller is showing an Option Card External Fault, it means an external fault signal was received from the PLC or there's a problem with the PLC program. To resolve this:
1. Remove the source of the external fault.
2. Reset the external fault input from the PLC.
Also, check the PLC program for any issues.
B
Brenda CostaAug 25, 2025
Why does my YASKAWA SI-EP3 show Option Fault?
R
Roberto HartAug 25, 2025
If the YASKAWA Controller displays an Option Fault, it means an option of the same type is already installed in option port CN5-A, CN5-B, or CN5-C. To fix this, connect the option to the correct option port.
R
Renee SmithAug 26, 2025
What to do if YASKAWA SI-EP3 Controller shows Option Card Connection Error (CN5-A)?
C
Chase FowlerAug 26, 2025
If a YASKAWA Controller displays an Option Card Connection Error (CN5-A), it means the option card connection to port CN5-A is faulty. To resolve this:
1. Turn off the power.
2. Check if the option is properly plugged into the option port.
3. If the fault continues, replace the option.
C
Curtis DawsonAug 27, 2025
What to do if YASKAWA Controller displays Option Card Error (CN5-A)?
E
elizabeth86Aug 28, 2025
If your YASKAWA Controller displays an Option Card Error (CN5-A), it signifies a fault in the option. To address this:
1. De-energize the drive.
2. Ensure the option is correctly connected to the connector.
3. If the problem persists, replace the option.
D
David WilsonAug 29, 2025
How to resolve Option Fault (CN5-B) on YASKAWA SI-EP3?
R
Robert ChenAug 29, 2025
If the YASKAWA Controller shows an Option Fault (CN5-B) and the option card installed into port CN5-A is incompatible with the drive, connect the option to the correct option port. Use connector CN5-B when connecting DO-A3, AO-A3, or two PG options. Use connector CN5-C when connecting only one PG option.
D
Daniel Chavez DDSAug 31, 2025
What causes Option Card Connection Error (CN5-A) on YASKAWA SI-EP3 Controller?
M
marymolinaAug 31, 2025
If your YASKAWA Controller displays an Option Card Connection Error (CN5-A), it means that the option card installed into port CN5-A is incompatible with the drive. Connect the option to the correct option port. Note that PG option cards are supported by option ports CN5-B and CN5-C only.
O
ortizjosephSep 2, 2025
How do I fix Option Fault (CN5-C) on a YASKAWA SI-EP3 Controller?
K
Kimberly MaxwellSep 3, 2025
If the YASKAWA Controller displays an Option Fault (CN5-C), it indicates that the option card installed into port CN5-C is incompatible with the drive. To resolve this, connect the option to the correct option port. Keep in mind that AI-A3, DI-A3, and communication options are not supported by option port CN5-C.
T
Tyler SolisSep 6, 2025
How to fix Option Card Connection Error (CN5-A) on YASKAWA SI-EP3?
W
webbhannahSep 6, 2025
If your YASKAWA Controller shows an Option Card Connection Error (CN5-A), it could be due to a faulty connection of the option card to port CN5-A. To resolve this:
1. Turn off the power.
2. Check if the option is properly plugged into the option port.
3. If the fault continues to occur, replace the option.
L
Laurie GibsonSep 9, 2025
What causes Option Card Fault (CN5-A) on YASKAWA SI-EP3?
H
hbarrettSep 9, 2025
If your YASKAWA Controller displays an Option Card Fault (CN5-A), it means the option connected to option port CN5-A was changed during run. To fix this, de-energize the drive and plug the option into the drive according to Installation Procedure.
A
anthony29Sep 12, 2025
Why does YASKAWA SI-EP3 Controller show Option Card Connection Error (CN5-A)?
R
Ryan MolinaSep 12, 2025
If your YASKAWA Controller displays an Option Card Connection Error (CN5-A), the installed option card might be incompatible with the drive. Connect the option to the correct option port. Note that PG option cards are supported by option ports CN5-B and CN5-C only.