EasyManuals Logo

YASKAWA SigmaLogic7 Compact User Manual

YASKAWA SigmaLogic7 Compact
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
4 Inputs and Outputs
4.2.1 200 V SERVOPACKS
21
4.2 Output Signals
4.2.1 200 V SERVOPACKS
Default settings are provided in parentheses.
Signal
Pin
No.
Name Function
ALM+ 3
Servo Alarm Output Turns OFF (opens) when an error is detected.
ALM- 4
/SO1+
(/BK+)
1
General-purpose Digi-
tal Output 1 (Brake
Output)
You can allocate the output signal to use with a parameter.
(Controls the brake. The brake is released when the signal
turns ON (closes).)
/SO1-
(/BK-)
2
/SO2+ 23
General-purpose Digi-
tal Output 2
Used for general-purpose outputs.
Set the parameters to allocate functions.
/SO2- 24
/SO3+ 25
General-purpose Digi-
tal Output 3
/SO3- 26
PAO 17 Encoder Divided
Pulse Output, Phase
A
Output the encoder divided pulse output signals with a 90°
phase differential.
/PAO 18
PBO 19 Encoder Divided
Pulse Output, Phase
B
/PBO 20
PCO 21 Encoder Divided
Pulse Output, Phase
C
Outputs the origin signal once every encoder rotation.
/PCO 22
SG 16 Signal ground This is the 0-V signal for the control circuits.
FG Shell Frame ground
Connected to the frame ground if the shield of the I/O Signal
Cable is connected to the connector shell.