5
.
Cont
.
6
.
7
.
SYMBOL
FUNCTION
ADJUSTMENT
13RH(C)
Time
adjustment
of
Adjust
to
60-120
sec
.
according
to
OVERLOAD
detection
specification
.
IORH(C)
Level
adjustmentof Adjust
to
110%
of
rated
speed
.
Over
Speed
detection
15RH(C)
Level
adjustmentof Adjust
to
84%
of
rated
voltage
.
Low
Voltage
detection
SYMBOL
FUNCTION
ADJUSTMENT
9RH(A)
Level
adjustment
of
Adjust
within
1% of
ratedspeed
.
zero
speed
detection
AGREE(A)
Level
adjustmentof
Adjust
to
x_15%
of
commanded
speed
speed
agree
detection
IORH(A)
Offset
adjustment
of Adjust
to
-
.15%
of
commanded
speed
at
low
speed
agree
detection
speed
range
.
(-15%)
I1RH(A)
Offset
adjustment
of Adjust
to
1-15%
of
the
commanded
speed
speedagree
detection
at
low
speed
.
(+15%)
DEV-A(A)
Level
adjustment
of
Adjust
to
50%of
the
commanded
speed
deviation
detection
SYMBOL
FUNCTION
ADJUSTMENT
TIME(A)
Selection
of acc/dec
time
limit
100%
speed
reference
T
is
equal
to
the
time
set
by
the
T
44
DIP
switch
.