External
TerminalList
Description
3-phase
200/220
VAC
±10%,
50/60
Hz
.
3-phase,
200/220
VAC
±10%,
50/60
Hz
Connect
U, V,
and
W
to
the
correspondingmotor
terminals
.
Connected
before
shipment
.
Normal
condition
:
Open
Detection
of
spindle
control
circuitabnormal
condition
:
Closed
32
is
connected
to
OV,
33
is
connected
to
speed
reference
(±1OV)
14
is
connected
to
OV,
13
to
resolver
terminal
C,
and
14 to
F
.
`10 is
connected
to
OV,
9 to
resolver
terminal
A,
land
10 to
0
.
~11
to
resolver
terminal
B
Connect
E
to
resolver
terminal
E
and ground
it
.
7 is
OV
common,
.
6 is
±12V,
8
is
-12V
.
1OmA
can
be
supplied
.
Usable
for
speed
setting,
etc
.
When +12V
is
applied
to
50,
torque
limit
is
ineffe-
ct
.
When
+12V
is
applied
to 37
interlock
is
not
ineffect
Terminal
Symbol
j
Name
R,
S,
T
Main
Power
Input
r, s,
t
Control
Power
Input
U,
V,
W Motor
Connection
v
CC
P,
B
Resistor
Connection
23,
25
SpindleCondition
Dete-
ction
23,
24
Spindle
Control
Abnorm
Detection
33,
32
Speed
Reference
Input
13,
14
Resolver
Input
9,
10
~esolver
Phase
A
Exci-
ftati
on
U
oC
11
Resolver
Phase
B
Exci-
tation
0
z
0
12
;Grounding
U
6,
7, 8
t12VOutput
50
Torque
Limit
37
Start
Interlock