4.5 STATUS DISPLAY BY SELF-DIAGNOSIS FUNCTION
(DGN)
When the 1/0 section of the NC unit is suspected of
failure,
diagnostic numbers can be keyed-in on the NC
control panel to display and check 1/O signals for
status.
4.5.1
OUTLINE OF DISPLAY
Table 4.46 Diagnostic Nos. and Contents
Diagnostic No.
I
Display Contents
#1000 to #1077
I
Input signals for machine too”
#1 100 to #1 175
10utput signals to machine tool
Output signals to power
#3500 to #3659
sequence
(PLC)
(standard
output signal)
I
Input signals to power
#3000 to #3119 sequence
(PLC)
(standard
output signal)
Remarks
Refer to machine manufacturer’s manual.
Refer to Appendix of
YASNAC i80M Instruction
Manual (TOE-C843-11.31) or Appendix of
YASNAC i80L Instruction Manual
(TOE-C843-11.21).
For details of signals, refer to YASNAC i80
Connecting Manual
(TOE-C843-11.5).
q
m.
1. With a power sequence (PC) setup built-in, the meanings of signals #1000 to #1077
and #1100 to #1175 depend on each power sequence program. Read the machine
manufacturer’s manual.
D,
D,
D,
D,
D,
D, D,
D,
Display : 0
001111
1
Co:tact
opened
~
Contact closed
2. For keep memory, refer to Section. 8, “ OPERATIONS OF FIXED FILES”.
.,-.
130