EasyManua.ls Logo

Yealink T54S

Yealink T54S
622 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Administrator’s Guide for SIP-T2 Series/T4 Series/T5 Series IP Phones
48
Default
Blank
Web UI
Network->Advanced->802.1x->Device Certificates
Parameter
static.network.802_1x.proxy_eap_logoff.enable
[1]
<y0000000000xx>.cfg
Description
It enables or disables the 802.1x-logoff feature for the PC port.
Permitted
Values
0-Disabled
1-Enabled, the 802.1x logoff message is sent to the authenticator when the PC is
disconnected.
Default
0
[1]
If you change this parameter, the IP phone will reboot to make the change take effect.
TR-069 Device Management
TR-069 is a technical specification defined by the Broadband Forum, which defines a mechanism that
encompasses secure auto-configuration of a CPE (Customer-Premises Equipment), and incorporates
other CPE management functions into a common framework. TR-069 uses common transport
mechanisms (HTTP and HTTPS) for communication between CPE and ACS (Auto Configuration Servers).
The HTTP(S) messages contain XML-RPC methods defined in the standard for configuration and
management of the CPE.
For more information on TR-069, refer to Yealink TR-069 Technote.
Topics
Supported RPC Methods
TR069 Configuration
Supported RPC Methods
The following table provides a description of RPC methods supported by IP phones.
RPC Method
Description
GetRPCMethods
This method is used to discover the set of methods
supported by the CPE.
SetParameterValues
This method is used to modify the value of one or more
CPE parameters.
GetParameterValues
This method is used to obtain the value of one or more
CPE parameters.
GetParameterNames
This method is used to discover the parameters accessible
on a particular CPE.

Table of Contents