4-19
IM 01F06A00-01E
4. BASIC OPERATING PROCEDURES
1 Device setup
2 PV [cr]
3 AO1 [cr]
4 Flow Span [cr]
5 Mode
4 Detailed setup
3 Configure outputs
4 Signal processing
Online Menu
to be continued to next page
1 Analog output
2
Contact output [#][u/d]
<B20>
3 Display mode
4 Totalizer
5 HART output
Blank [r&w sel]
Total
(Temp)
1 Set noise ratio[r&w] <K26>
2 End
1 Flow span[r&w][u/d] <B10>
2 Outlimit(H)[r&w][u/d] <D30>
3 Burn out[r] <D35>
1 TLA[r&w] [u/d] <K10>
2 Signal level[r&w] [u/d] <K20>
3
Noise balance mode [u/d]<K25>
4 Noise ratio[cr or w][u/d] <K26>
5 Maintenance data
6 Error record <K40>
7 High vibration[u/d] <K45>
8 Amplifier check
9 Menu type number
10 Menu type
1
PV Damp[r&w][u/d]<B15>
2
Low cut[r&w][u/d]<D10>
3 Temp setup
4 Density setup
5 Maintenance
1 Temp unit [u/d] <D20> (*5)
2
Process temp[r&w][u/d]<D21>
1 Pulse rate[r&w][u/d] <B21>
Off
Scaled pulse
Unsdcled pulse
Frequency
Alarm
Flow SW(Low:On)
Flow SW(Low:Off)
1 Frequency at 100%[r&w][u/d] <B22>
1 Setting level[r&w][u/d] <B23>
1 Upper display[u/d] <B30>
2 Lower display[u/d] <B31>
Flow rate(%) [r&w sel]
Flow rate
{Temp(%)}
1 Total[cr] <A30>
2 Total start/stop[u/d] <B40>
3 Total rate[r&w][u/d] <B45>
4 Total reset[w,#] <B47>
Stop [r&w sel]
Start
1 Poller addr[r&w]
2 Num req preams[r]
3 Burst mode
4 Burst option
Off [r&w sel]
On
PV [w sel]
%range/current
Process vars/crnt
1 Density unit [u/d] <D25> (*6)
2
Process density[r&w][u/d]<D26>
Auto [r&w sel]
Manual
Tuning at zero flow
1 Velocity[cr] <K30>
2 Span velosity[cr] <K32>
3 Vortex frequency[cr]
4 Span frequency[cr] <K36>
(5 Density) <K38>
Err record reset[w,#]
Er record status 1[cr] (*11)
Er recprd status 2[cr] (*12)
(Er record status 3[cr]) (*13)
0% [r&w sel]
No action
1 Set vortex frequency[r&w] <K28>
2 End
to be continued to next page
F040608_4.EPS
<K34>
[r] : read
[cr] : continuous read
[w] : write
[u/d] : upload/download data
[sel] : select
[#] : method
{ } : Only for
Option code /MV
< > : Parameter No.
in display and BRAIN
Terminal
( ) : Related parameter