48 IM 04P01B01-02E
Clearing the Alarm Printout Buffer
Alarm information waiting to be printed is temporarily stored in the buffer memory. This
operation clears all of the alarm information in the buffer. This function can be used to
prevent unneeded alarm printouts from being executed.
1.
Press the
FUNC
key.
2.
Press the key to select Buffer clear and then press the key.
Func=Buffer clear
3.
Press the key with Alarm shown on the screen.
The data in the alarm printout buffer is cleared. The screen returns to the data
display screen.
Buf.clear=Alarm
Printing a Message
This section explains the procedure for printing the preset character strings. For details
on setting the character strings, see section 6.8, “Setting the Message String” in the
µ
R10000 Recorder User’s Manual
(IM 04P01B01-01E) on the CD-ROM.
Note
Messages can be printed only during trend recording. However, regardless of whether
trend recording is in progress or not, messages waiting to be printed are temporarily
stored in the buffer memory.
Message printouts are not performed when the chart speed is greater than or equal to
1600 mm/h and 101 mm/h on the pen model and dot model, respectively.
Printing a Message
1.
Press the
FUNC
key.
2.
Press the key to select Message and then press the key.
Func=Message
3.
Press the key to select the message number and then press the key.
The message printout starts. The screen returns to the data display screen.
Displays the preset message.
Message=Message1
Clearing the Message Printout Buffer
Messages waiting to be printed are temporarily stored in the buffer memory. This
operation clears the messages in the buffer.
1.
Press the
FUNC
key.
2.
Press the key to select Buffer clear and then press the key.
3.
Press the key to select Message and then press the key.
The data in the message printout buffer is cleared. The screen returns to the
data display screen.
Buf.clear=Message
Recording/Displaying Data
* When the key or key is pressed while holding down the SHIFT key, the operation is
reversed as when the respective key is pressed by itself.

Table of Contents

Other manuals for YOKOGAWA MuR10000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA MuR10000 and is the answer not in the manual?

YOKOGAWA MuR10000 Specifications

General IconGeneral
BrandYOKOGAWA
ModelMuR10000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals