036-21233-002-A-0903
Unitary Products Group 9
TABLE 4: DNH024 COOLING CAPACITIES - 2 TON
TEMPERATURE
OF AIR ON
CONDENSER COIL
AIR ON EVAPORATOR COIL
600 CFM 700 CFM 800 CFM 900 CFM 1000 CFM
WB °FWB °FWB °FWB °FWB °F
72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57
85 °F
NET CAP.
MBH
23.1 22.8 20.2 19.7 24.5 24.1 21.4 20.9 25.9 25.5 22.6 22.0 25.3 25.0 22.1 21.6 24.8 24.4 21.6 21.1
TOTAL POWER
INPUT kW
2.00 1.99 1.98 1.97 2.03 2.02 2.01 2.00 2.06 2.05 2.04 2.03 2.10 2.09 2.08 2.07 2.15 2.14 2.12 2.11
Sensible Capacity
MBH
1
Entering Dry
Bulb °F
86 12.1 16.6 19.2 19.3 14.6 19.5 20.9 20.7 17.0 22.3 22.6 22.0 15.9 21.3 22.1 21.6 14.8 20.2 21.6 21.1
83 11.5 16.0 18.6 18.7 13.3 18.2 20.6 20.4 15.0 20.4
22.6 22.0 14.5 19.9 22.1 21.6 14.0 19.5 21.6 21.1
80 10.9 15.4 17.9 18.1 12.0 16.9 19.7 19.9 13.0 18.4 21.5 21.6 13.1 18.5 21.6 21.4 13.3 18.7
21.6 21.1
77 10.3 14.8 17.3 17.5 10.7 15.6 18.4 18.6 11.1 16.4 19.5 19.7 11.8 17.2 20.2 20.0 12.5 17.9 20.9 20.4
74 9.7 14.1 16.7 16.9 9.4 14.3 17.1 17.3 9.1 14.4 17.5 17.7 10.4 15.8 18.8 18.7 11.7 17.2 20.1 19.6
71 - 13.5 16.1 16.3 - 13.0 15.8 16.0 - 12.5 15.5 15.7 - 14.4 17.4 17.3 - 16.4 19.3 18.8
68 - 12.9 15.5 15.6 - 11.7 14.5 14.7 - 10.5 13.6 13.8 - 13.1 16.1 15.9 - 15.6 18.6 18.1
95°f
NET CAP.
MBH
22.8 21.8 19.1 18.7 23.7 22.6 19.9 19.4 24.6 23.5 20.6 20.2 24.3 23.2 20.4 19.9 24.0 22.9 20.1 19.7
TOTAL POWER
INPUT kW
2.17 2.13 2.13 2.11 2.20 2.16 2.16 2.14 2.22 2.19 2.19 2.17 2.28 2.24 2.24 2.22 2.33 2.30 2.29 2.27
Sensible Capacity
MBH
1
Entering Dry
Bulb °F
86 14.4 18.6 19.1 18.7 15.7 20.4 19.9 19.4 17.1 22.2 20.6 20.2 16.1 21.3 20.4 19.9 15.1 20.4 20.1 19.7
83 12.6 16.8 18.5 18.5 13.8 18.5 19.6 19.3 15.0 20.1
20.6 20.2 14.6 19.9 20.4 19.9 14.3 19.7 20.1 19.7
80 10.8 15.1 16.7 16.7 11.8 16.5 18.3 18.3 12.8 17.9 19.9 19.8 13.2 18.4 20.0 19.8 13.5 18.9
20.1 19.7
77 9.0 13.3 15.0 14.9 9.8 14.5 16.4 16.3 10.7 15.8 17.8 17.7 11.7 16.9 18.6 18.3 12.8 18.1 19.3 18.9
74 7.2 11.5 13.2 13.0 7.9 12.6 14.4 14.3 8.6 13.6 15.7 15.6 10.3 15.5 17.1 16.8 12.0 17.3 18.6 18.1
71 - 9.7 11.4 11.3 - 10.6 12.4 12.4 - 11.5 13.5 13.4 - 14.0 15.7 15.4 - 16.6 17.8 17.4
68 - 7.9 9.6 9.5 - 8.6 10.5 10.4 - 9.4 11.4 11.3 - 12.6 14.2 13.9 - 15.8 17.0 16.6
105°F
NET CAP.
MBH
20.9 18.9 17.0 16.2 21.9 19.9 17.8 17.0 23.0 20.8 18.7 17.8 23.2 20.9 18.8 17.9 23.3 21.1 18.9 18.0
TOTAL POWER
INPUT kW
2.32 2.27 2.28 2.26 2.35 2.30 2.31 2.29 2.37 2.33 2.33 2.32 2.43 2.38 2.39 2.37 2.48 2.44 2.44 2.42
Sensible Capacity
MBH
1
Entering Dry
Bulb °F
86 12.6 16.1 16.5 16.0 14.0 17.9 17.6 16.9 15.3 19.6 18.7 17.8 15.3 19.7 18.8 17.9 15.2 19.8 18.9 18.0
83 11.4 15.0 15.9 15.6 12.7 16.6 17.3 16.7 13.9 18.2 18.6
17.8 14.2 18.7 18.8 17.9 14.5 19.1 18.9 18.0
80 10.3 13.8 14.8 14.5 11.4 15.3 16.4 16.0 12.6 16.8 18.0 17.6 13.1 17.6 18.5 17.8 13.7 18.3
18.9 18.0
77 9.1 12.6 13.6 13.3 10.1 14.0 15.1 14.8 11.2 15.4 16.6 16.2 12.1 16.5 17.4 16.7 13.0 17.6 18.2 17.3
74 8.0 11.5 12.4 12.1 8.9 12.8 13.8 13.5 9.8 14.0 15.2 14.8 11.0 15.4 16.3 15.7 12.2 16.9 17.5 16.5
71 - 10.3 11.3 11.0 - 11.5 12.5 12.2 - 12.6 13.8 13.4 - 14.4 15.3 14.6 - 16.1 16.7 15.8
68 - 9.1 10.1 9.8 - 10.2 11.3 10.9 - 11.3 12.4 12.1 - 13.3 14.2 13.5 - 15.4 16.0 15.0
115°F
NET CAP.
MBH
19.0 16.1 14.9 13.7 20.2 17.1 15.8 14.6 21.3 18.1 16.7 15.4 22.0 18.6 17.3 15.9 22.7 19.2 17.8 16.4
TOTAL POWER
INPUT kW
2.46 2.42 2.42 2.41 2.49 2.45 2.45 2.44 2.53 2.48 2.48 2.47 2.58 2.53 2.54 2.52 2.63 2.58 2.59 2.57
Sensible Capacity
MBH
1
Entering Dry
Bulb °F
86 10.9 13.6 13.8 13.3 12.2 15.3 15.3 14.4 13.6 17.0 16.7 15.4 14.5 18.1 17.3 15.9 15.3 19.2 17.8 16.4
83 10.3 13.1 13.3 12.8 11.6 14.7 15.0 14.1 12.9 16.4
16.7 15.4 13.8 17.4 17.2 15.9 14.6 18.5 17.8 16.4
80 9.8 12.5 12.8 12.3 11.0 14.1 14.4 13.8 12.3 15.7 16.0
15.4 13.1 16.8 16.9 15.9 13.9 17.8 17.8 16.4
77 9.3 12.0 12.2 11.7 10.4 13.5 13.8 13.2 11.6 15.1 15.4 14.7 12.5 16.1 16.2 15.2 13.2 17.1 17.1 15.7
74 8.7 11.5 11.7 11.2 9.9 13.0 13.2 12.7 11.0 14.4 14.7 14.1 11.7 15.4 15.5 14.5 12.5 16.4 16.3 14.9
71 - 10.9 11.2 10.7 - 12.4 12.5 12.1 - 13.8 14.1 13.5 - 14.7 14.9 13.8 - 15.6 15.6 14.2
68 - 10.4 10.6 10.1 - 11.8 12.0 11.5 - 13.2 13.5 12.8 - 14.0 14.2 13.2 - 14.9 14.9 13.5
125°F
NET CAP.
MBH
17.2 13.3 12.8 11.3 18.5 14.3 13.8 12.1 19.7 15.4 14.8 13.0 20.9 16.4 15.7 13.9 22.1 17.4 16.6 14.7
TOTAL POWER
INPUT kW
2.61 2.56 2.57 2.55 2.64 2.59 2.60 2.59 2.68 2.62 2.63 2.62 2.73 2.67 2.68 2.67 2.78 2.72 2.73 2.72
Sensible Capacity
MBH
1
Entering Dry
Bulb °F
86 9.1 11.1 11.2 10.7 10.4 12.7 13.0 11.8 11.8 14.4 14.8 13.0 13.6 16.4 15.7 13.9 15.5 18.6 16.6 14.7
83 9.2 11.2 10.7 10.0 10.5 12.8 12.7 11.5 11.9 14.5 14.7
13.0 13.3 16.2 15.7 13.9 14.8 18.0 16.6 14.7
80 9.3 11.3 10.8 10.1 10.6 13.0 12.4 11.6 12.0 14.6 14.0
13.0 13.0 15.9 15.3 13.9 14.1 17.3 16.6 14.7
77 9.4 11.4 10.9 10.2 10.7 13.1 12.5 11.7 12.1 14.7 14.2 13.0 12.7 15.6 15.1 13.6 13.4 16.6 15.9 14.0
74 9.5 11.5 11.0 10.3 10.8 13.2 12.6 11.8 12.2 14.8 14.3 13.0 12.5 15.4 14.8 13.4 12.7 15.9 15.2 13.3
71 - 11.6 11.1 10.4 - 13.3 12.7 11.9 - 15.0 14.4 13.0 - 15.1 14.5 13.1 - 15.2 14.5 12.6
68 - 11.7 11.2 10.4 - 13.4 12.8 12.0 - 15.1 14.5 13.0 - 14.8 14.2 12.8 - 14.5 13.8 11.9
1.
These capacities are net capacities (the indoor fan heat is deducted).