chapter5. Troubleshooting
Can’t turn on the
equipment
The circuit breaker in the
electrical control box isn’t turned
on
Turn on the circuit breaker
Intermediate relay is damaged
Replace the intermediate relay
Check and repair the short
circuit
Can’t turn on the
laser /
galvanometer
Control button is damaged
Replace the control button
Control switching power supply is
damaged
Replace the switching power
supply of same model
Intermediate relay is damaged
Replace the intermediate relay
Can’t find the
control card
External switching power supply
is damaged
Replace the switching power
supply
Control card power cord plug is
loose
USB cable isn’t plugged in
properly
Reinsert the USB cable properly
Driver is uninstalled or not
installed
Control card is damaged
Replace the control card
Correction parameter is incorrect
Modify the correction
parameters
Modify the scale parameter
Galvanometer signal cable isn’t
plugged in properly
Check the signal cable interface
and plug properly