3.4 "PARAMETER CHANGE" MENU
3.4.a Pallet truck
ACCELER. DELAY Acceleration time; 9 = maximum time
DECELER. DELAY Deceleration time; 9 = maximum time
RELEASE BRAKING Release braking time; 9 = max. braking power, minimum
time
INVERS. BRAKING Inversion braking time; 9 = max. braking power, minimum
time
CUTBACK SPEED 1 Speed reduction 1
CUTBACK SPEED 2 Speed reduction 2
MAX FORW. SPEED Maximum forward speed
MAX BACK. SPEED Maximum reverse speed
TRACTION IMAX Maximum current (it's a function of the parameter
MAXIMUM CURRENT)
CREEP SPEED Initial step voltage
BACKING TIME Backing time
BACKING SPEED Fixed speed during backing function
SEAT MICRO DELAY Seat microswitch release delay time (if the “Handle
Switch option” is configured as “Seat”); or delay between
direction request and tiller (if the “Handle Switch option”
is configured as “Present”).
HYDRO TIME Delayed disengaging of hydro output.
3.4.b Floor washer
ACCELER. DELAY Acceleration time; 9 = maximum time
DECELER. DELAY Deceleration time; 9 = maximum time
RELEASE BRAKING Release braking time; 9 = max. braking power, minimum
time
INVERS. BRAKING Inversion braking time; 9 = max. braking power, minimum
time
CUTBACK SPEED 1 Speed reduction 1
CUTBACK SPEED 2 Speed reduction 2
MAX FORW. SPEED Maximum forward speed
MAX BACK. SPEED Maximum reverse speed
TRACTION IMAX Maximum current (it's a function of the parameter
MAXIMUM CURRENT)
CREEP SPEED Initial step voltage
AUXILIARY TIME Delayed disengaging of auxiliary output NEV2.
HYDRO TIME Delayed disengaging of hydro output (NEV1).