Check up type
None Programmed maintenance function disengaged; no
alarm, no reduction, no shut down.
Option #1 Programmed maintenance function enabled; an alarm
message is visualised after 300 hours.
Option #2 Programmed maintenance function enabled; an alarm
message is visualised after 300 hours and a speed
reduction is enabled after 340 hours
Option #3 Programmed maintenance function enabled; an alarm
message is visualised after 300 hours, speed reduction is
enabled after 340 hours and the traction is blocked after
380 hours.
3.9 "SPECIAL ADJUST" MENU
Set temperature Fine adjustment of chopper temperature (the chopper
temperature is calibrated by Zapi during testing and
should not be modified by the client).
Maximum Current Adjust the maximum chopper current. A password is
required in order to modify this setting and remains active
until the key is turned off.
3.10 "CLEAR EEPROM" MENU
Clear EEprom can be effected from this menu; this virtually resets the plant and cancels
the settings entered up to that moment. At the end of the Clear EEprom operation the
original settings (default values) are reloaded. Clear EEprom has no effect on the
following settings:
- Model Type
- Maximum Current
- Set temperature
- Adjust Battery