Page 20
Set battery type
Sets the battery nominal value
24V 24V battery.
36V 36V battery.
3.6.b Floor washer
Hour counter
Running The hour counter is active during running only.
Key on The hour counter is active at all times.
Battery check
Off Battery alarm disengaged.
On Low battery alarm enabled (plus current limiting device).
Quick inversion
Belly Quick inversion is active while the button remains
Timed Timed quick inversion (set duration).
Inversion Mode
Option #1 The quick inversion input is configured as normally open.
Option #2 The quick inversion input is configured as normally
closed.
Automatic function
Off To be defined.
On The NEV2 output is active during running and is
disengaged with a programmable delay time. The output
is always disengaged when a low battery alarm is
present.
Aux function #2
The tiller/seta switch is not used by cleaning machine, so the input can be used for
other purpose.
Option #1 The “Tiller/Seat” input is a switch that activates the NEV1
output. When the switch is opened the output is
disengaged with a delay time that is programmed by the
“Hydro Time” parameter.
Option #2 The “Tiller/Seat” input is a button that activates the NEV1
output when pressed once. Pressing a second time
disengages the output with a delay time that is
programmed by the “Hydro Time” parameter.