Page 19
Handle switch
Present Tiller present: incorrect start if pressed at key-on and
movement jammed if released during running. A maximum
delay time between selecting the running direction and
selecting the tiller can be programmed using the “Seat micro
delay” parameter.
Seat Seat present: no incorrect start is pressed at key-on, delay
if released during running (program the delay time using the
“Seat micro delay” parameter). The seat-running sequence
is compulsory.
Aux output #2 (NEV1 output)
This option is only effective if “Set input # 2” is set to “Option #1”.
Option #1 The NEV1 output acts as a hydro: it is active during running
and is set at rest with a programmable delay time after
running.
Option #2 The NEV1 output is activated when a thermal alarm is
present (e.s. can be used to activate a fan)
Set input #2
Option #1 The “Aux output #2” and “Backing function” options can be
used.
Option #2 The “Aux output #2” and “Backing function” options have no
effect. The “RV2” input is not a speed reduction but is used
as a button (Toggle); the NEV1 output is activated by an
“RV2” impulse and disengaged by a second impulse.
Inversion Mode
Option #1 The quick inversion input is configured as normally open.
Option #2 The quick inversion input is configured as normally closed.
Aux function #2
Option #1 The potentiometer is configured with an electric range of 0V-
5V. Forward and backward micros are present.
Option #2 The potentiometer is configured with an electric range of 0V-
2.5V-5V (2.5V is the ‘at rest’ value). Forward and backward
micros are not used; the direction is given by the voltage on
the potentiometer unit:
2,5V 5V = backward

Related product manuals