EasyManuals Logo

Zapi ACEX User Manual

Zapi ACEX
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
AFCZP0BC – COMBIACX & ACEX - User Manual Page - 47/81
38) MAX EVP
From 0 to 100. This parameter determines the maximum current applied to the
EVP when the position of the potentiometer is at the maximum. This parameter
also determines the current value when the EVP is programmed like an
ON/OFF valve.
39) EVP OPEN DELAY
Seconds. It determines the acceleration ramp on EVP.
The parameter sets the time needed to increase the current to the maximum
possible value.
40) EVP CLOSE DELAY
Seconds. It determines the deceleration ramp on EVP.
The parameter sets the time needed to decrease the current from the maximum
possible value to zero.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi ACEX and is the answer not in the manual?

Zapi ACEX Specifications

General IconGeneral
BrandZapi
ModelACEX
CategoryInverter
LanguageEnglish

Related product manuals