19) DI4/BACKWARD SW.
ON/OFF. This is the level of the digital input CNB#8 for the backward travel
demand:
- ON +VB = When it is closed to a battery (key) voltage, the Backward Travel
demand is Active.
- OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND), the Backward Travel demand is not active.
20) DI5/HORN SWITCH
ON/OFF. This is the level of the digital CNA#4:
- ON +VB = When it is closed to a battery (key) voltage the HORN request is
active.
- OFF GND = When it is not closed to a battery (key) voltage (or connected to
GND) the HORN request is not active.
21) DI6/LOWERING SW.
ON/OFF. This is the level of the digital input CNA#11:
- ON +VB = When it is closed to a battery (key) voltage, the request of the
Lowering request is active.
- OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND), the Lowering request is not active.
22) DI7/LIFT SWITCH
ON/OFF. This is the level of the digital input CNA#5:
- ON +VB = When it is closed to a battery (key) voltage the voltage the
LIFTING request is active.
- OFF GND = When it is not closed to a battery (key) voltage (or connected to
GND) the voltage the LIFTING request is not active.
23) DI8/1ST P.SPEED
ON/OFF. This is the level of the digital input CNA#12:
- ON +VB = When it is closed to a battery (key) voltage the 1ST request is
active.
- OFF GND = When it is not closed to a battery (key) voltage (or it is
connected to GND) the 1ST request is not active.
24) DI9/LIFT CUTBACK
ON/OFF. This is the level of the digital input CNA#6:
- ON GND = When it is closed not to a battery (key) voltage (or it is
connected to GND), the PUMP CUTBACK request is not active.
- OFF +VB = When it is closed to a battery (key) voltage, the PUMP
CUTBACK request is active.
25) DI10/2ND P.SPEED
ON/OFF. This is the level of the digital input CNA#13:
- ON +VB = When is closed to a battery (key) voltage the digital the 2ND
request is active.
- OFF GND = When is not connected to a battery (key) voltage (or it is
connected to GND) the 2ND request is not active.
26) DI11/CUTBACK1
ON/OFF. This is the level of the CNA#7 digital input:
- ON GND = When CNA#7 is not closed to GND the CUTBACK1 request not
is active.