AFCZP0BC – COMBIACX & ACEX - User Manual Page - 53/81
- OFF +VB = When is not connected to GND (or it is connected to battery) the
CUTBACK1 request is active.
27) DI12 CUTBACK 2
ON/OFF. This is the level of the digital input CNA#14:
- ON GND = When CNA#14 is not closed to GND the CUTBACK2 request
not is active.
- OFF +VB = When is not connected to GND (or it is connected to battery) the
CUTBACK2 request is active.
28) SET POINT EVP
This parameter shows the setpoint of EVP valve.
29) EV1 FEEDBACK
ON/OFF. This parameter shows the feedback of EV1 valve.
30) EV2 FEEDBACK
VOLTAGE %. This parameter shows the feedback of EV2 valve.
31) EV3 FEEDBACK
VOLTAGE %. This parameter shows the feedback of EV3 valve.
32) OUTPUT EV1
ON/OFF. This is the EV1 output command.
33) OUTPUT EV2
%. This is the EV2 output command (voltage %).
34) OUTPUT EV3
%. This is the EV3 output command (voltage %).
35) OUTPUT HORN
ON/OFF. This is the HORN output command.
36) MAIN CONT. VOLT.
%. This is the main contactor output command (voltage %).
37) ELEC. BRAKE VOLT.
%. This is the electrobrake output command (voltage %).