Page - 28/36 ADPZP0CC - MHYRIO FLASH CONTROLLER - User Manual
12) EV #4
It indicates the state of the electrovalve 4 (CNG5). Options:
- ON = active entry of closed switch (equal to battery positive potential)
- OFF = inactive entry of open switch (equal to GND potential)
13) EV #5
It indicates the state of the electrovalve 5 (CNG4). Options:
- ON = active entry of closed switch (equal to battery positive potential)
- OFF = inactive entry of open switch (equal to GND potential)
14) EV #6
It indicates the state of the electrovalve 6 (CNG3). Options:
- ON = active entry of closed switch (equal to battery positive potential)
- OFF = inactive entry of open switch (equal to GND potential)
15) EV #7
It indicates the state of the electrovalve 7 (CNG2). Options:
- ON = active entry of closed switch (equal to battery positive potential)
- OFF = inactive entry of open switch (equal to GND potential)
16) EV #8
It indicates the state of the electrovalve 8 (CNG1). Options:
- ON = active entry of closed switch (equal to battery positive potential)
- OFF = inactive entry of open switch (equal to GND potential)
17) STATUS #1
It indicates the state of the STATUS1 electrovalve (CNF4). Options:
- ON = active entry of closed switch (equal to battery positive potential)
- OFF = inactive entry of open switch (equal to GND potential)
18) STATUS #2
It indicates the state of the STATUS2 electrovalve (CNF3). Options:
- ON = active entry of closed switch (equal to battery positive potential)
- OFF = inactive entry of open switch (equal to GND potential)
19) STATUS #3
It indicates the state of the STATUS3 electrovalve (CNF2). Options:
- ON = active entry of closed switch (equal to battery positive potential)
- OFF = inactive entry of open switch (equal to GND potential)
20) ENCODER
It indicates the digital count of encoder. This value will be acquired by
SICOS. In this menu, it's present only for functionality check of encoder.
21) ANALOG INPUT #1
It indicates the voltage relative to analog input 1. The value is between 0 and
255. Every step corresponds to 1/256 of maximum voltage.
22) ANALOG INPUT #2
It indicates the voltage relative to analog input 2. The value is between 0 and
255. Every step corresponds to 1/256 of maximum voltage.
23) ANALOG INPUT #3
It indicates the state of the AS1 analog select (CNF7).
24) ANALOG INPUT #4
It indicates the state of the AS2 analog select (CNF8).