8 PERIODIC MAINTENANCE TO BE REGULARLY REPEATED
Check outwear of electric contacts: they should be replaced when matchboard is too
strong and worn-out. Electric contacts should be checked every 3 months.
Check pedal microswitch: verify with a tester that there is no electric resistance be-
tween the contacts by measuring the voltage drop between its terminals. Also the re-
lease should have a firm sound. The pedal microswitch should be checked every 3
months.
Check motor-battery power links: they should be in excellent shae as well as the wires'
claddings. Wires should be checked every 3 months.
Control of the pedal and contactors springs. They should be able to extend to its full
extention and checked every 3 months.
Check contactors mechanical movements. They should be frictionfree and not stick.
Mechanical movements of the contactors should be checked every 3 months.
Checks should be done by skilled personnel only and, all spare parts should be original.
Installation of this electronic controller should be done according to the diagrams in-
cluded in this manual and any variation should be done accordingly with the supplier.
The supplier is not responsible for any problem that rises from using wiring solutions
different from the ones suggested on this manual.
Any cause which is visible or realizable by an ordinary technician who periodically
checks the equipment, that can create damages or defects to the device should be
transmitted to the ZAPI's technician or to the technical commercial net.
They will take the responsibility for possible decisions regarding the functioning safety of
the electric vehicle.
DO NOT USE A VEHICLE WITH A
FAULTY ELECTRONIC CONTROLLER
H2B