Router(config)# no alg sip direct-signalling
Router(config)# no alg sip direct-media
Test result
Connect SIP phone to the USG, and check the register status. Register successfully.
Figure 205
Check the SIP register status on PBX.
Figure 206
What could go wrong?
SIP phone does not support transform itself, but the “SIP Transformations” does not be
checked.
Figure 207
SIP phone will contact with outside as not direct-signalling and direct media, but the
default setting on USG is on