User Guide 2N® EasyGate PRO
Information SMS
Forced information SMS
Demanded by SMS in form: EG INF 12345 (instead of ‘12345’ actual password)
The answer of the Gateway:
EG.INF OK demand accepted
SN:00-0000-0000 serial number
FW:18.7.16 FW version
LIC:N (or Y) license for function 3 Lift1 on line
IMEI:358108071238512 IMEI
IMSI:230015011042680;230025100127093 IMSI (eventually 2. SIM)
LAI:230;01;H;3G MCC, MNC, roaming (H/R), technol.
RSSI:-77dBm Strength of signal
PWR:On Line power
BATT:Ok Battery status
EXP:730 Time to battery change (days)
Dual SIM gateway will send both IMSI, but information about network and signal strength is for
active connection only.
Periodical SMS
Sending is connected by parameter ‘Checking SMS’. When this parameter is set to 0, no SMS
except forced SMS are sent, another setting specifies the period of information SMS sending in
days and allows SMS sending in following situations:
Restart of the gateway: GW start
Changing of used SIM SIM switch
Change in power status PWR change
Periodical SMS Periodical
Line of the SMS with connection information marked as Active shows actual information, line
without this mark shows last known information (important for dual SIM gateway). When the
parameter ‘ID text’ is not filled in, the parameter ‘Id number’ is used, when even this parameter
is empty, the serial number will be used.
SMS format is:
ID:Filled (text) or SN:xx-xxxx-xxxx Identification
Msg:GW start or another code Code of the event
SIM1:23001;Home;3G;-83dBm;Active MCC+MNC, roaming, technology, signal