Alarm
Aastra 632d 115
eud-1586/1.0 – R3.0 – 04.2013
Trigger procedure
Alarm message sequence Signalling on the phone User interaction
Detection phase:
The phone detects an alarm sit-
uation. The detection duration
starts to run (see Detection
duration setting).
No signalling No interaction
Pre-alarm phase:
The phone signals a pre-alarm.
Alarm delay starts to run (see
Alarm cancellation delay set-
ting).
• Progressive signalling ring.
Rings for several seconds
and repeats itself. This ring-
ing cannot be switched off.
• Vibracall, if activated.
• LED indicator flashes fast
and red.
Pressing any key resets the
alarm. The alarm message is
not sent to the alarm system.
Alarm phase:
The phone sends the alarm to
the alarm system.
Depending on the configura-
tion of the alarm system an
alarm melody sounds. Rings
until the alarm system
acknowledges receipt of the
alarm message or the set ring-
ing duration (see Alarm confir-
mation time) expires.
Pressing any key resets the
alarm.
The subsequent procedure depends on how the alarm system is configured. Contact your system
administrator for more information.