bdiRDI
JTAG interface for RDI Debuggers, BDI1000 User Manual 35
© Copyright 1999-2003 by ABATRON AG V 1.10
Appendices
A Troubleshooting
Problem
The firmware can not be loaded.
Possible reasons
The BDI is not correctly connected with the target system (see chapter 2).
The power supply of the target system is switched off or not in operating range
(2.5 VDC ... 5 VDC) --> MODE LED is OFF or RED
The built in fuse is damaged --> MODE LED is OFF
The BDI is not correctly connected with the Host (see chapter 2).
• A wrong communication port (Com 1...Com 4) is selected.
Problem
No working with the target system (loading firmware is ok).
Possible reasons
Wrong pin assignment (BDM/JTAG connector) of the target system (see chapter 2).
Target system initialization is not correctly --> enter an appropriate target initialization list.
• An incorrect IP address was entered (BDI1000 configuration)
• BDM/JTAG signals from the target system are not correctly (short-circuit, break, ...).
The target system is damaged.
Problem
Network processes do not function (loading the firmware was successful)
Possible reasons
The BDI1000 is not connected or not correctly connected to the network (LAN cable or media
converter)
• An incorrect IP address was entered (BDI1000 configuration)