261Gx, 261Ax | IM/261Gx/Ax-EN Rev. 08  7 
 
 
 
 
 
 
1.8  Compliance with Pressure Equipment Directive 
(2014/68/EU) 
 
Devices with PS > 200 bar (20 MPa) 
Devices with a permissible pressure of PS > 200 bar (20 MPa) 
have been tested for conformity by the Technical Supervisory 
Association TÜV NORD (0045) in accordance with module H 
and can be used for fluids of group 1 (PED: 1G). 
The name plate bears the following identification codes: 
 
 
Fig. 3:  Identification codes according to Pressure Equipment 
Directive (example) 
1  PED: 1G  |  2  Identification number of the notified body according 
to the Pressure Equipment Directive  |  3  "SIL 2" identification code 
(optional) 
 
Devices with PS ≤ 200 bar (20 MPa) 
Devices with a permissible pressure PS ≤ 200 bar (20 MPa) 
conform to sec. 3 para. (3) and have not been tested for 
conformity. The devices have been constructed and 
manufactured according to sound engineering practice (SEP). 
The CE marking on the device does not refer to the Pressure 
Equipment Directive. 
The name plate then contains the following identification 
codes: PED: SEP. 
 
 
1.9  Transport safety instructions 
 
Observe the following instructions: 
—  Do not expose the device to humidity during transport. 
Pack the device accordingly. 
—  Pack the device so that it is protected against vibrations 
during transport, e.g., by using air-cushioned packaging. 
 
 
Prior to installation, check the devices for possible damage 
that may have occurred as a result of improper transport. 
Details of any damage that has occurred in transit must be 
recorded on the transport documents. All claims for damages 
must be submitted to the shipper without delay and before 
installation. 
 
 
 
 
 
 
 
 
 
1.10  Storage conditions 
 
—  The device must be stored in dry and dust-free conditions. 
Always keep the device in its original package during 
storage / transport. 
—  Observe the permissible ambient conditions for transport 
and storage according to the chapter “Technical Data”. 
—  In principle, the devices may be stored for an unlimited 
period. However, the warranty conditions stipulated in the 
order confirmation of the supplier apply. 
 
 
1.11  Safety instructions for electrical installation 
 
The electrical connection may only be established by 
authorized specialist personnel and in accordance with the 
connection diagrams. 
The electrical connection information in this manual must be 
observed; otherwise, the IP rating may be adversely affected. 
Ground the measurement system according to requirements. 
 
 
1.12  Safety instructions for operation 
 
Before switching on the device, make sure that your 
installation complies with the environmental conditions listed in 
the chapter “Technical Data” or on the data sheet. 
If there is a chance that safe operation is no longer possible, 
take the device out of operation and secure it against 
unintended startup. 
 
 
1.13  Returning devices 
 
Use the original packaging or a secure transport container of 
an appropriate type if you need to return the device for repair 
or recalibration purposes. Fill out the return form (see the 
Appendix) and include this with the device. 
According to the EU Directive governing hazardous materials, 
the owner of hazardous waste is responsible for its disposal or 
must observe the following regulations for shipping purposes: 
All devices delivered to ABB must be free from any hazardous 
materials (acids, alkalis, solvents, etc.). 
 
 
Please contact Customer Center Service acc. to page 2 for 
nearest service location.