EasyManuals Logo

ABB 266HSH Operating Instructions

ABB 266HSH
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
2600T Series Pressure transmitters | OI/266/LowP-EN Rev.A 3
Contents
Index
1 Introduction ..........................................................4
1.1 Instruction manual structure ......................................... 4
1.2 Models covered by this manual ..................................... 4
1.3 Product description ...................................................... 4
2 Safety ....................................................................5
2.1 General safety information ............................................ 5
2.2 Improper use ................................................................ 5
2.3 Technical limit values .................................................... 5
2.4 Warranty prevision ........................................................ 5
2.5 Use of instruction ......................................................... 5
2.6 Operator liability ........................................................... 6
2.7 Qualified personnel ....................................................... 6
2.8 Returning devices......................................................... 6
2.9 Disposal ....................................................................... 6
2.10 Information on WEEE Directive 2002/96/EC ................ 6
2.11 Transport and storage ................................................ 6
2.12 Safety information for electrical installation .................. 6
2.13 Safety information for inspection and maintenance ...... 6
3 Transmitter overview .............................................7
3.1 Transmitter components overview ................................. 7
3.2 Range & Span consideration ......................................... 8
4 Opening the box ...................................................9
4.1 Identification ................................................................. 9
4.2 Optional wired-on SST plate (I1) .................................... 9
4.3 Handling ...................................................................... 9
4.4 Storage ........................................................................ 9
5 Mounting ............................................................. 10
5.1 General ...................................................................... 10
5.2 IP protection & designation ......................................... 10
5.3 Mounting the transmitter............................................. 10
5.3.1 Transmitter factory configuration consideration .... 10
5.3.2 Hazardous area considerations ........................... 10
5.4 Pressure Equipment Directive (PED) (97/23/CE)........... 10
5.4.1 Devices with PS >200 ......................................... 10
5.4.2 Devices with PS 200 bar ................................... 10
5.5 Mounting a P style pressure transmitter ...................... 11
5.5.1 B1 and B2 Barrel housing bracket details ............ 13
5.6 Transmitter housing rotation........................................ 13
5.7 Impulse piping connection for standard instruments .... 13
6 Transmitter wiring ............................................... 14
6.1 Cable connection ....................................................... 14
6.2 Analogue output (HART) transmitter wiring .................. 14
6.3 Supply requirement .................................................... 15
6.4 Wiring procedure ........................................................ 15
6.5 Grounding .................................................................. 16
6.6 Surge protector equipped terminal block (optional) ...... 16
6.7 Common mode voltages ............................................ 16
7 Commissioning ................................................... 17
7.1 Analague and HART Communication models .............. 17
7.2 Standard setting for error detection (alarm).................. 17
7.3 Write Protection ......................................................... 17
7.3.1 Write protection activation via dip switch.............. 17
7.4 Securing the housing cover in flameproof areas ...... 17
8 Operation ............................................................ 18
8.1 Factory settings ........................................................ 18
8.2 Configuration types .................................................... 18
8.3 Configuring the transmitter with LCD keys ................... 18
8.4 LRV and URV configuration (1 ... 5 V ranging) ............. 18
8.5 Activation procedure for the integrated LCD ................ 19
8.6 HMI as feedback of the local push button operations .. 19
8.7 HMI menu structure .................................................... 19
8.7.1 Easy Set-up ........................................................ 20
8.8 Hardware settings: dip-switch functionality .................. 21
8.9 Damping .................................................................... 21
8.10 Transfer function ....................................................... 21
8.10.1 Linear ............................................................... 21
8.10.2 Custom linearization curve ................................. 22
8.10.3 Cylindrical lying tank ......................................... 22
8.10.4 Spherical Tank ................................................. 22
8.11 Configuration with the PC or HHT ............................ 22
9 Error messages ................................................... 23
9.1 LCD Display ............................................................... 23
9.2 Error states and alarms .............................................. 23
10 Maintenance ..................................................... 25
10.1 Returns and removal ................................................ 25
10.2 Pressure transmitter sensor ...................................... 25
10.3 Pressure transducer replacement .............................. 25
10.4 Electronic replacement ............................................. 25
11 Hazardous area consideration .......................... 26
11.1 Ex Safety aspects and IP Protection (North America) . 26
11.1.1 Applicable standards ......................................... 26
11.1.2 Classifications ................................................... 26
Trouble Sheet .........................................................27
Return Report ........................................................ 28

Table of Contents

Other manuals for ABB 266HSH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB 266HSH and is the answer not in the manual?

ABB 266HSH Specifications

General IconGeneral
TypePressure Transmitter
MaterialStainless Steel
Temperature Range-40 to 85°C (-40 to 185°F)
Output Signal4-20 mA
Process Connection1/2 in. NPT
Ingress ProtectionIP67
Electrical Connection1/2 in. NPT, M20 x 1.5

Related product manuals