EasyManua.ls Logo

ABB ACS 400 - Page 102

ABB ACS 400
187 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACS 400 Users Manual 91
Group 22: Accel/Decel
Two acceleration/deceleration ramp pairs can be used. If both ramp pairs are used, the selection
can be made between these in run time through a digital input. The S curve of the ramps is
adjustable.
Figure 31 Definition of acceleration/deceleration ramp time.
Code Description
2201 ACC/DEC 1/2 SEL
Selects the source for the ramp pair selection signal.
0 =
NOT SEL
The first ramp pair is used (ACCELER TIME 1/DECELER TIME 1).
1...5 = DI1...DI5
Ramp pair selection is done through a digital input (DI1 to DI5).
Digital input deactivated = Ramp pair 1 (
ACCELER TIME 1/DECELER TIME 1) is used.
Digital input activated = Ramp pair 2 (
ACCELER TIME 2/DECELER TIME 2) is used.
2202 ACCELER TIME 1
Ramp 1: time from zero to maximum frequency (0 -
MAXIMUM FREQ).
2203 DECELER TIME 1
Ramp 1: time from maximum frequency to zero (
MAXIMUM FREQ - 0).
2204 ACCELER TIME 2
Ramp 2: time from zero to maximum frequency (0 -
MAXIMUM FREQ).
2205 DECELER TIME 2
Ramp 2: time from maximum frequency to zero (
MAXIMUM FREQ - 0).
2206 RAMP SHAPE
Acceleration/deceleration ramp shape selection
0 =
LINEAR
1 = FAST S CURVE
2 = MEDIUM S CRV
3 = SLOW S CURVE
Linear
S curve
Ramp time
Time
MAXIMUM FREQ
Output frequency
http://nicontrols.com

Table of Contents

Other manuals for ABB ACS 400

Related product manuals