EasyManua.ls Logo

ABB ACS180-04S-03A7-1 - Typical Power Cable Sizes

ABB ACS180-04S-03A7-1
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Frame
size
NoiseAir flow
Typical power loss
1)
ACS180-04...
dB(A)CFMm
3
/hBTU/hW
R26277130663194.2-17A5-2
R366751281345394.2-25A0-2
R366751281431419.5-033A-2
R469881501924563.8-048A-2
R469881502330683-055A-2
3-phase
U
n
= 380 ... 480 V
R0---7321.3-01A8-4
R0---10530.9-02A6-4
R0---12636.8-03A3-4
R151213615344.9-04A0-4
R151213623267.9-05A6-4
R151213629285.5-07A2-4
R1512136405118.7-09A4-4
R26277130530155.3-12A6-4
R26277130821240.5-17A0-4
R366751281310383.9-25A0-4
R366751281829536-033A-4
R469881501675490.8-038A-4
R469881501960574.5-045A-4
R469881502273666.2-050A-4
1)
Typical drive losses when it operates at 90% of the motor nominal frequency and 100% of the drive
nominal output current.
Typical power cable sizes
FrameAWG
Cable conductor sizes (mm
2
)
1)
ACS180-04...
1-phase
U
n
= 208 ... 240 V
R0163×1.5 + 1.5-02A4-1
R0163×1.5 + 1.5-03A7-1
R0163×1.5 + 1.5-04A8-1
R1163×1.5 + 1.5-06A9-1
R1143×2.5 + 2.5-07A8-1