EMC compatibility and motor cable length
To comply with the EMC limits in the European EMC Directive (standard IEC/EN
61800-3), use these maximum motor cable lengths for the 4 kHz switching
frequency.
Maximum motor cable length, 4 kHzFrame
Class 3Class 2
Class 1
1)
ftmftmftm
With internal EMC filter
1-phase
U
n
= 208 ... 240 V
3310165--R0
3310165--R1
3310165--R2
3-phase
U
n
= 380 ... 415 V
3310----R0
3310----R1
3310----R2
9830----R3
9830----R4
With optional external EMC filter
1-phase
U
n
= 208 ... 240 V
--98303310R0
--98303310R1
--98303310R2
3-phase
U
n
= 208 ... 240 V
98309830--R0
98309830--R1
98309830--R2
66206620--R3
66206620--R4
3-phase
U
n
= 380 ... 415V
--98303310R0
--98303310R1
--98303310R2