See figure F:
Attach the drive module to the pedestal guide plate.
Attach the drive module from top to the punched section at the cabinet
Connect the power cables and install the shrouds
FigureTask (motor cables)Step
JInstall the grounding terminal to the drive module base.1
KRun the motor cables to the cabinet. Ground the cable shields 360° at the cabinet
entry.
2
LConnect the twisted shields of the motor cables to the grounding terminal.3
MScrew in and tighten the insulators to the drive module by hand. Install the T3/W2
connection terminal to the insulators.
4
Do not use longer screws or bigger tightening torque than given in
the installation drawing. They can damage the insulator and cause
dangerous voltage to be present at the module frame.
NConnect the phase T3/W2 conductors to the T3/W2 terminal.5
-Install the T2/V2 connection terminal to the insulators. See the warning in step 4.6
-Connect the phase T2/V2 conductors to the T2/V2 connection terminal.7
-Install the T1/U2 connection terminal to the insulators. See the warning in step 4.8
-Connect the phase T1/U2 conductors to the T1/U2 terminal.9
O, PIf there is no bottom plate in the cabinet and degree of protection of IP20 is needed:10
Step drill carefully sufficiently big holes to the inner clear plastic shrouds for the
motor cables to the connected. Smooth the hole edges. Cut the shroud from
the holes to the edge to make it possible to put the shroud around the cables.
Remove the plastic sheeting from the shrouds from both sides.
Install the inner clear plastic shrouds around the motor cables.
QRemove the plastic sheeting from the outer clear plastic shroud from both sides.
Install the shroud to the drive module.
11
QInstall the lower front cover to the drive module.12
FigureTask (input cables)Step
-
Ground the input cable shields (if present) 360° at the cabinet entry.1
-Connect the twisted shields of the input cables and separate ground cable (if
present) to the cabinet grounding busbar.
2
RStep drill carefully sufficiently big holes to the clear plastic entry shroud for the
cables to the connected. Align the holes in the vertical direction according to the
alignment holes in the shroud. Smooth the hole edges.
3
Remove the plastic sheeting from both sides of the shroud.
Attach the cables firmly to the cabinet frame to prevent chafing against the hole
edges.
SPut the conductors of the input cables through the drilled holes in the clear plastic
shroud.
4
TConnect the input power cable conductors to the L1/U1, L2/V1 and L3/W1 connection
busbars.
5
UMove the clear plastic entry shroud along input cables to its final position. Install
the front clear plastic shroud and upper front cover. Remove the cardboard protect-
ive covering from the drive module air outlet.
6
12 EN Quick installation instructions