118
Preventive Maintenance
3ADW000488R0101 DCS880 Service manual e a
Make sure all supply voltages are switched off, most important the supply for the power part
(armature), for the drive electronics (SDCS-POW-H01), for the converter fan and for other auxiliaries!
Open the cabinet’s and module’s door; if needed secure them.
Pull the torque indication spring a little bit out:
Release the torque indication spring. It has to snap back into position “correct torque”:
If the torque indicating spring does not snap back into position “correct torque” the stack has to be
retorqued otherwise everything is fine.
Tighten each nut in turn, half a turn at a time with the help of a ring spanner until the indicating spring
clicks into position “correct torque”. Do not tighten the screws any further.