62 Start-up
7. Select the drive, eg, Drive 1 (FECA-01 and ACSM1 motion),
and then select the Process Data tab of the drive.
On this tab, you can configure and assign PDOs to Sync
Managers.
Rx PDOs are transmitted from the master to the module.
Tx PDOs are transmitted from the module to the master.
Rx PDOs are assigned to Sync manager 2 (Outputs) and
Tx PDOs are assigned to Sync manager 3 (Inputs).
By pressing the Load PDO info from device button, the
current PDO configuration on the module is loaded into the
TwinCAT System Manager with which the PDO
configuration can be viewed.