80 Communication profiles
6 RAMP_IN_ZERO 1 Normal operation.
Proceed to OPERATION.
Note: This is effective only if the
fieldbus interface is set as the
source for this signal by drive
parameters.
0 Force the Ramp Function
Generator input to zero.
7 RESET 0=>1 A fault is reset if an active fault
exists.
Proceed to SWITCH-ON
INHIBITED.
Note: This is effective only if the
fieldbus interface is set as the
source for this signal by drive
parameters.
0 Continue normal operation.
8…9 Drive-specific
10 REMOTE_CMD 1 Fieldbus control is enabled.
0 Control word and reference not
getting through to the drive,
except for CW bits OFF1, OFF2
and OFF3.
11 EXT_CTRL_LOC 1 Select External Control Location
EXT2.
This is effective if the control
location is parametrized to be
selected from the fieldbus.
0 Select External Control Location
EXT1.
This is effective if the control
location is parametrized to be
selected from fieldbus.
12…
15
Reserved