NoteAction
xx1300002420
Pull out the axis-3 motor connectors from the
housing and disconnect them.
3
Removing the cable package in the housing
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 158.
2
xx1300002422
Remove the screw that fastens the air hose hold-
er.
3
Continues on next page
Product manual - IRB 1200 505
3HAC046983-001 Revision: S