NoteAction
Guide pin for upper arm: 3HAC049705-001Fit guide pins to the upper arm.7
Always use three guide pins together!
xx1400000771
xx1300002533
Separate the upper and lower arm with
guidance from the guide pins.
8
Removing the axis-3 drive unit
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See Cut the paint or surface on the robot before
replacing parts on page 158.
2
Continues on next page
Product manual - IRB 1200 673
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.6.3 Replacing the axis-3 drive unit
Continued