NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
1
See the figure in:
Location of the cable harness on
page 201 (Cable harness, lower arm)
Cut the cable strap on the lower arm.2
A
B
C
D
xx0900000020
Remove the brackets on the lower arm.3
Parts:
A: Bracket, lower arm
B: Bracket, lower arm
C: Bracket, armhouse
D: Cable bracket
Continues on next page
210 Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.3.1 Removing the complete cable harness
Continued