Storage conditions, robot
The table shows the allowed storage conditions for the robot:
ValueParameter
-25° CMinimum ambient temperature
+55° CMaximum ambient temperature
+70° CMaximum ambient temperature (less than 24 hrs)
95% at constant temperature
(gaseous only)
Maximum ambient humidity
Operating conditions, robot
The table shows the allowed operating conditions for the robot:
ValueParameter
+5°CMinimum ambient temperature
+45°CMaximum ambient temperature
95% at constant temperatureMaximum ambient humidity
Protection classes, robot
The table shows the available protection types of the robot, with the corresponding
protection class.
Protection class
i
Protection type
IRB 2600: IP 67Manipulator, protection type Standard
IRB 2600ID upper arm: IP 54
IP 67Manipulator, protection type Foundry Plus
i
According to IEC 60529.
48 Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
2 Installation and commissioning
2.2.2 Technical data
Continued

Table of Contents