No. Name/Value/Range Description Default
FbEq (16b/32b)
107 System info
107.04 Firmware name Shows the inverter firmware name. - / 1 = 1
107.05 Firmware version Shows the inverter firmware version. - / 1 = 1
107.06 Loading package name Shows the inverter loading package name. - / 1 = 1
107.07 Loading package version Shows the inverter loading package version. - / 1 = 1
107.20 LCON HW version Shows the HW version of the LCON board. -
0 … 255 1 = 1
107.21 LUAC HW version Shows the HW version of the LUAC board. -
0 … 255 1 = 1
107.22 LUFU HW version Shows the HW version of the LUFU board. -
0 … 255 1 = 1
107.23 LUPU HW version Shows the HW version of the LUPU board. -
0 … 255 1 = 1
107.30 Product name1 Holds part of the Product Name of the inverter.
The Product Name is obtained by concatenating
parameters "Product name1" ... "Product name6"
into a string. Each parameter contains 4 ASCII
characters represented as a 32 decimal number.
0
- - / 1 = 1
... ... ... ...
107.36 Product name7 See parameter 107.30 Product name1 - / 1 = 1
107.40 Product serial number1 Holds part of the serial number of the inverter.
The serial number is obtained by concatenating
parameters "Product serial number1" ... "Product
serial number6" into a string. Each parameter
contains 4 ASCII characters represented as a 32
decimal number.
0
- - / 1 = 1
... ... ... ...
107.46 Product serial number7 See parameter 107.40 Product serial number1 0
- - / 1 = 1
107.50 CB serial number1 Holds part of the control board serial number of
the inverter. The complete serial number is
obtained by concatenating all the "CB serial
number" parameters into a string. Each
parameter contains 4 ASCII characters
represented as a 32 decimal number. Characters
are arranged from left to right in the 32 bit integer.
0
- - / 1 = 1
... ... ... ...