96 Parameters
No. Name/Value/Range Description Default
FbEq (16b/32b)
196 System
196.01 Language Selects language. -
Not selected Language is not selected. 0
English US English (United States) 1033
Deutsch German (Germany) 1031
Italiano Italian (Italy) 1040
Español Spanish (Spain 3082
Français French (France) 1036
196.02 Passcode Allows typing passcode to activate further access
levels, for example, additional parameters.
-
196.06 Param restore Restores original settings of the application, that
is, the parameter factory default values.
Done
Done Restoring is completed. 0
Restore defs All parameter values are restored to default
values, except Ext-IO, fieldbus and operation
settings.
8
Clear all All parameter values are restored to default
values.
62
196.07 Param save Saves valid parameter values to the permanent
memory.
Note: A new parameter value is saved
automatically when changed from the PC tool or
panel but not when changes through a fieldbus
connection.
Done
Done Save completed. 0
Save Save in progress. 1
196.08 Control board boot Changing this value to one (1) reboots the control
board.
Note: Before changing the value, make sure
inverter is disabled with parameter 189.01
Inverter operation.
-
0 … 1 1 = 1
196.24 Full days since 1st Jan
1980
Sets day count starting from 1st of January 1980
(= 1).
This parameter together with 196.25 Time in
minutes within 24 h and 196.26 Time in ms within
one minute makes it possible to set the date and
time in the inverter via the fieldbus parameter
interface.
-
1 ... 59999 Days since beginning of year 1980. 1 = 1 day
196.25 Time in minutes within 24 h Sets the number of full minutes passed since
midnight. For example, the value 860
corresponds to 2:20 pm.
See parameter 196.24 Full days since 1st Jan
1980.
-
0 ... 1439 min Minutes since midnight. 1 = 1 min