EasyManua.ls Logo

ABB ProcessMaster FEP630 - Page 71

ABB ProcessMaster FEP630
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FEP630, FEH630 ELECTROMAGNETIC FLOWMETER | CI/FEP630/FEH630-EN REV. D 71
Flowmeter sensor in high temperature version
***
Lining material Flange material Ambient temperature range (T
amb
) Measuring medium temperature (T
medium
)
Minimum Maximum Minimum Maximum
Thick PTFE*** Steel -10 °C (14 °F) 60 °C (140 °F) -10 °C (14 °F) 180 °C (356 °F)
Thick PTFE*** Stainless steel -20 °C (-4 °F) 60 °C (140 °F) -20 °C (-4 °F) 180 °C (356 °F)
Æ40 °C (-40 °F)**
PFA*** Steel -10 °C (14 °F) 60 °C (140 °F) -10 °C (14 °F) 180 °C (356 °F)
PFA*** Stainless steel -20 °C (-4 °F) 60 °C (140 °F) -20 °C (-4 °F) 180 °C (356 °F)
Æ40 °C (-40 °F)**
ETFE*** Steel -10 °C (14 °F) 60 °C (140 °F) -10 °C (14 °F) 130 °C (266 °F)
ETFE*** Stainless steel -20 °C (-4 °F) 60 °C (140 °F) -20 °C (-4 °F) 130 °C (266 °F)
Æ40 °C (Æ40 °F)**
* Only for China production site
** For (optional) low-temperature version only
*** Only for design level ‘A’

Table of Contents

Related product manuals