EasyManua.ls Logo

ABB PT003915 - Table 36: Malfunctions When Stopping - Runout Time too Short; Table 35: Malfunctions When Stopping - Runout Noises; Malfunctions When Stopping

ABB PT003915
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / Power2 340-H / High-pressure stage
8 Troubleshooting / 8.4 Malfunctions when stopping
© Copyright 2022 ABB. All rights reserved. HZTL4054_EN Rev.F March 2022
8.4 Malfunctions when stopping
Runout noises
Possible causes Remedy
Low-pressure
or
high-pressure
stage
Pressure stage contaminated Clean
Bearing damaged Contact a Turbo Systems service sta-
tion
Rotor rubbing
Foreign object in the pressure stage
Table35: Malfunctions when stopping – Runout noises
Runout time too short
Possible causes Remedy
Low-pressure
or
high-pressure
stage
Pressure stage contaminated Clean
Bearing damaged Contact a Turbo Systems service sta-
tion
Rotor rubbing
Foreign object in the pressure stage
Table36: Malfunctions when stopping – Runout time too short