81
Table 15. ErrorCode1 with PNIORW decoding
Read block is used in read requests and responses. Write block is
used in write requests and responses. The request consists of
Error class Meaning Error code
0…9 (Reserved)
10 (0x0A) Application 0 = Read error
1 = Write error
2 = Module failure
3…7 = Reserved
8 = Version conflict
9 = Feature not supported
10 15 = User-specific
11 (0x0B) Access 0 = Invalid index
1 = Write length error
2 = Invalid slot
3 = Type conflict
4 = Invalid area
5 = State conflict
6 = Access denied
7 = Invalid range
8 = Invalid parameter
9 = Invalid type
10 15 = User-specific
12 (0x0C) Resource 0 = Read constraint conflict
1 = Write constraint conflict
2 = Resource busy
3 = Resource unavailable
4…7 = Reserved
8 15 = User-specific
13 15 User-specific