Communication
92
I&M0 Device identification (read-only)
I&M1 Task identification
I&M2 Installation date
Content Size Description
Header 10 bytes -
Vendor ID 2 bytes PROFINET Vendor ID of ABB, which is 26
(0x001A)
Order ID 20 bytes Order number of the RETA-02 adapter kit
Serial number 16 bytes Serial number of the adapter
Hardware revision 2 bytes Hardware revision of the RETA-02 adapter
Software revision 4 bytes Revision of the software
Revision counter 2 bytes Number of revision
Profile ID 2 bytes PROFIdrive (0x3A00)
Profile specific type 2 types No profile specific type (0x0000)
I&M version 2 types Version is 1.1 (0x0101)
Supported I&M
functions
2 types I&M0-I&M4 are supported (0x0017)
Content Size Description
Header 10 bytes -
TAG_FUNCTION 32 bytes The function or task of the drive can be
described here
TAG_LOCATION 22 bytes The location of the drive can be described here
Content Size Description
Header 10 bytes -
INSTALLATION_DATE 16 bytes This parameter indicates the date and time
of installation. Date and time according to
ISO 8601. Example: 2007-02-28 13:30
(YYYY-MM-DD hh:mm)