VIRUS CLASSIC MANUAL 353
Appendix
SYSTEM-EXCLUSIVE-MESSAGE
SYSEX PARAMETER CHANGE
Example: {F0,00,20,33,01,dd,7x,pp,nn,vv,F7}
The SysEx Parameterchange affects one of the sixteen single edit buffer in Multi Mode addressed by
the part number (00..0F) or the Single buffer in Single Mode (part number 40). If a global parameter
or a Multi parameter is accessed, which is not part-sensitive (e.g. Input Boost or Multi Delay Time),
the part number is ignored.
Example: F0,00,20,33,01,10,70,05,28,5F,F7 (Set Cutoff on Part 6 to decimal value 95. (10: device ID
omni; 70: page A, 05: part 6; 28: parameter Cutoff, 5F: decimal value 95)
Byte Meaning Remark
F0 Start of System Exclusive
00 Manufacturer ID 1 Access Music Electronics
20 Manufacturer ID 2 Access Music Electronics
33 Manufacturer ID 3 Access Music Electronics
01 Product ID (Virus)
dd Device ID 00..0F, individual; 10: omni.
... [message] Message Body
F7 End of System Exclusive
Byte Meaning Remark
7x Parameterchange 70:page A; 71:page B; 72:page C
pp Part number 00..0F: Multi part 1..16;
40: Single
nn Parameter Number

Table of Contents