128
MIDI PANEL DESTINATION
ARPEGGSEND
This parameter determines whether or not (ON or OFF, respectively) the arpeggiator sends the notes
it generates to the MIDI Out. This function is a feasible option only when you want to address further
sound generators via MIDI.
If you want to record notes generated by the Arpeggiator to a sequencer, please ensure that these
are not sent directly back to the Virus. If you fail to do this, the Arpeggiator may no longer be able to
play correctly under these conditions. To avoid this situation, route data via another MIDI channel or
switch off the MIDI Thru function on your sequencer.
CLOCK RX
This parameter activates or deactivates the receiving of MIDI-Clock globally. The Virus automati-
cally detects the presence of MIDI-Clock (Auto). Therefore this parameter is not intended to switch
MIDI-Clock on, but to switch it off if you should feel that this is necessary (Off).
MIDI VOLUME ENABLE
Globally switches the reception of Volume data (Controller #7) on (ENA) or off (DIS).
PROGRAM CHANGE ENABLE
Globally swithes the reception of Program Change Data for SINGLE programs on and off.
Mode Description
INTERNAL
All types of control operations are sent directly to the Virus sound genera-
tion components and not to the MIDI Out.
INT+MIDI
All types of control operations are sent directly to the Virus sound genera-
tion components and simultaneously to MIDI Out.
MIDI
All types of control operations are sent exclusively to MIDI-Out, the internal
signal path is severed. This position is equivalent to the classic Local Off
function for the user interface.