User Manual Facility Performance Testing 7-
b. Check for visible damage or
tampering to the zone equipment.
c. Have a maintenance technician
verify power to the zone equipment
d. Call your Accutech Representative.
7. To reset the zone, enter a Keypad reset,
deactivate the test Tag, and, if
necessary, clear the alarm on the PC.
Zone, Elevator Deactivation Test
When a Tag approaches an elevator zone the
elevator call buttons will be disabled. This test
will evaluate this operation.
1. Notify staff and security that you will be
testing zone performance and alarms
will be generated. They should pay
special attention to traffic during this
time.
2. Using an S-TAD, activate the test Tag.
3. Enter the elevator zone. The zone’s
response will depend on the state of the
elevator door(s):
a. Elevators with door(s) open will
disable as you approach and an
alarm will sound. The car will not
be able to leave the floor.
b. Elevators with door(s) closed will
have their call button(s) disabled.
c. Elevators en route will arrive, open,
and then an alarm will sound. The
car will not be able to leave the
floor.
4. Verify this alarm is logged on the
central computer and any other remote
computers networked to it.
5. Record the results (pass or fail)
6. If the test fails to cause an alarm:
a. Notify staff and security of the
vulnerable area.
b. Check for visible damage or
tampering to the zone equipment.
c. Have a maintenance technician
verify power to the zone equipment
d. Have a maintenance technician
verify the FPI is set properly
e. Call your Accutech Representative.
7. To reset the zone, deactivate the test Tag
and, if necessary, enter a Keypad reset
and clear the alarm on the PC.
Door Ajar Test
This test will evaluate the Door Ajar feature.
1. Notify staff and security that you will be
testing zone performance and alarms
will be generated. They should pay
special attention to traffic during this
time.
2. Without a Tag in the zone, prop the door
open.
3. Depending upon the time delay setting,
the door should register a Door Ajar
alarm after the predetermined time.
4. Record and verify the time setting.